All categories / Before you go to the counter

Before you go to the supply counter

Bring the equipment model and serial number, the old part, and the numbers printed on it. With those three, a counter can match almost anything. This site is a reference and does not sell parts, so the right contact is one of the people listed further down.

CU1What to bring every time

  1. The equipment nameplate. Brand, full model number and serial number, copied exactly or photographed. On outdoor units it is on the cabinet near the service valves. On furnaces and air handlers it is inside the door.
  2. The old part itself. Labels wear off and descriptions are vague, but the part in hand can be measured and cross-referenced.
  3. Photos before you disconnect anything. One wide shot of the wiring, one close shot of each terminal with its wire color visible, and one of the wiring diagram on the panel.
  4. The supply voltage. 115 or 208/230 V, single or three phase, and 24 V for controls.

Take the photos even if you are sure you will remember. A contactor has four to six wires on it and they all look the same on the bench.

CU2What to write down, by part

The numbers that match each part
PartWrite downWhere to find itMore
MotorHP, volts, phase, RPM, FLA, frame, rotation with viewing end, capacitor µF, shaft diameter and lengthMotor nameplate. Measure the shaftCP1
CapacitorµF value, or both values on a dual, and voltage rating. Round or ovalPrinted on the canCT2
ContactorPoles, amp rating, coil voltagePrinted on the side and on the coilCT3
FilterActual dimensions and depth, MERV, quantitySmall print on the filter frame, or measure the slotFL1
Copper tubeOutside diameter of each line, length, soft or hardMeasure with a calliper. ACR tube is sized by ODPR2
RefrigerantType and charge weightEquipment nameplate, never from memorySV2
CompressorModel from the shell, refrigerant, volts and phase, RLA and LRACompressor label and unit nameplateCP3
ThermostatTerminal letters in use, system type (conventional or heat pump, stages), whether a C wire is presentOld thermostat sub-base. Photograph itCT1
Pressure or limit switchOpening and closing values, reset type, mountingStamped on the switch bodyCT5
Coil cleanerIndoor or outdoor coil, coil construction, what is on itLook at the coilCH1
Duct and fittingsDiameter or width by height, lengths, gauge, a count of fittingsMeasure, and sketch the runDS1
Condensate pumpLift in feet, voltage, what drains into itMeasure pump to highest point of the tubeCP4

If a number is unreadable, say so. A counter can often work back from the equipment model to the original part, but only if nobody has guessed in the meantime.

CU3Which purchases need EPA 608 certification

PurchaseCertification needed to buy
Refrigerant in cylinders, including R-410A, R-454B, R-32, R-134a and reclaimed R-22Yes. Sold only to Section 608 certified technicians or their employers
Equipment shipped with a factory charge, such as a condensing unitSale policies vary by seller. Connecting it to a field-piped system and opening its valves is work for a certified technician
Recovery cylinders, gauges, vacuum pumps, leak detectorsNo, though using them on a charged system is certified work
Motors, capacitors, contactors, thermostats, filters, chemicals, ductNo

Wholesale supply houses mostly sell to trade accounts. Some serve walk-in customers for general parts and some do not, so ask before you drive over. The certification types and the exam are explained under Section 608 certification.

CU4Who to contact for what

The right contact for each need
You needContactHave ready
A part under manufacturer warrantyThe equipment brand's authorized distributor, usually through the installing contractor. Warranty parts are processed by the distributor for that brand, not by any counter that stocks a lookalikeModel, serial, installation date, and registration details if the unit was registered
A general replacement part out of warrantyA wholesale supply house or parts distributorThe lists on this page
Work on the refrigerant circuitA contractor with Section 608 certified techniciansModel and serial, and a description of the symptom
Gas, venting or new electrical circuitsA contractor licensed for that trade in your stateModel and serial, and what changed before the problem began
Disposing of recovered refrigerantAn EPA-certified refrigerant reclaimer, or a supply house that collects cylinders for oneTagged cylinders, one refrigerant in each, with weights
Scrapping a unit that still holds refrigerantA certified technician to recover the charge first, then a scrap or appliance recyclerProof of recovery, which recyclers ask for
Installation or service instructions, wiring diagramsThe equipment manufacturer's literature for the exact modelFull model number
A safety data sheetThe chemical's manufacturer or the seller. See reading an SDSExact product name
A lost Section 608 cardThe certifying organization that gave your examName and approximate test date

The EPA publishes the list of certified reclaimers and the list of approved Section 608 certifying organizations. How reclaim works at a drop-off point is under how a reclaim drop-off works.

CU5How to ask

Lead with the equipment, then the part, then the numbers: "Three ton heat pump, this model, I need the dual run capacitor, 45 over 5 at 440." That order lets the counter person check your numbers against what the unit should have, which catches the case where the last person fitted the wrong part.

  • Say what the part does, if you do not know its name. "The switch on the burner box with the red button" is a rollout switch.
  • Ask whether the replacement is the original equipment part or a universal one, and what differs, such as mounting or wire leads.
  • Ask what else is normally replaced with it. A new motor wants a new capacitor. An opened refrigerant circuit wants a new filter drier.
  • Ask about returns before buying electrical parts. Many counters do not take them back once installed.

New to all of this? The category index shows how a supply house is laid out, and about this reference explains how the pages work.