CU1What to bring every time
- The equipment nameplate. Brand, full model number and serial number, copied exactly or photographed. On outdoor units it is on the cabinet near the service valves. On furnaces and air handlers it is inside the door.
- The old part itself. Labels wear off and descriptions are vague, but the part in hand can be measured and cross-referenced.
- Photos before you disconnect anything. One wide shot of the wiring, one close shot of each terminal with its wire color visible, and one of the wiring diagram on the panel.
- The supply voltage. 115 or 208/230 V, single or three phase, and 24 V for controls.
Take the photos even if you are sure you will remember. A contactor has four to six wires on it and they all look the same on the bench.
CU2What to write down, by part
| Part | Write down | Where to find it | More |
|---|---|---|---|
| Motor | HP, volts, phase, RPM, FLA, frame, rotation with viewing end, capacitor µF, shaft diameter and length | Motor nameplate. Measure the shaft | CP1 |
| Capacitor | µF value, or both values on a dual, and voltage rating. Round or oval | Printed on the can | CT2 |
| Contactor | Poles, amp rating, coil voltage | Printed on the side and on the coil | CT3 |
| Filter | Actual dimensions and depth, MERV, quantity | Small print on the filter frame, or measure the slot | FL1 |
| Copper tube | Outside diameter of each line, length, soft or hard | Measure with a calliper. ACR tube is sized by OD | PR2 |
| Refrigerant | Type and charge weight | Equipment nameplate, never from memory | SV2 |
| Compressor | Model from the shell, refrigerant, volts and phase, RLA and LRA | Compressor label and unit nameplate | CP3 |
| Thermostat | Terminal letters in use, system type (conventional or heat pump, stages), whether a C wire is present | Old thermostat sub-base. Photograph it | CT1 |
| Pressure or limit switch | Opening and closing values, reset type, mounting | Stamped on the switch body | CT5 |
| Coil cleaner | Indoor or outdoor coil, coil construction, what is on it | Look at the coil | CH1 |
| Duct and fittings | Diameter or width by height, lengths, gauge, a count of fittings | Measure, and sketch the run | DS1 |
| Condensate pump | Lift in feet, voltage, what drains into it | Measure pump to highest point of the tube | CP4 |
If a number is unreadable, say so. A counter can often work back from the equipment model to the original part, but only if nobody has guessed in the meantime.
CU3Which purchases need EPA 608 certification
| Purchase | Certification needed to buy |
|---|---|
| Refrigerant in cylinders, including R-410A, R-454B, R-32, R-134a and reclaimed R-22 | Yes. Sold only to Section 608 certified technicians or their employers |
| Equipment shipped with a factory charge, such as a condensing unit | Sale policies vary by seller. Connecting it to a field-piped system and opening its valves is work for a certified technician |
| Recovery cylinders, gauges, vacuum pumps, leak detectors | No, though using them on a charged system is certified work |
| Motors, capacitors, contactors, thermostats, filters, chemicals, duct | No |
Wholesale supply houses mostly sell to trade accounts. Some serve walk-in customers for general parts and some do not, so ask before you drive over. The certification types and the exam are explained under Section 608 certification.
CU4Who to contact for what
| You need | Contact | Have ready |
|---|---|---|
| A part under manufacturer warranty | The equipment brand's authorized distributor, usually through the installing contractor. Warranty parts are processed by the distributor for that brand, not by any counter that stocks a lookalike | Model, serial, installation date, and registration details if the unit was registered |
| A general replacement part out of warranty | A wholesale supply house or parts distributor | The lists on this page |
| Work on the refrigerant circuit | A contractor with Section 608 certified technicians | Model and serial, and a description of the symptom |
| Gas, venting or new electrical circuits | A contractor licensed for that trade in your state | Model and serial, and what changed before the problem began |
| Disposing of recovered refrigerant | An EPA-certified refrigerant reclaimer, or a supply house that collects cylinders for one | Tagged cylinders, one refrigerant in each, with weights |
| Scrapping a unit that still holds refrigerant | A certified technician to recover the charge first, then a scrap or appliance recycler | Proof of recovery, which recyclers ask for |
| Installation or service instructions, wiring diagrams | The equipment manufacturer's literature for the exact model | Full model number |
| A safety data sheet | The chemical's manufacturer or the seller. See reading an SDS | Exact product name |
| A lost Section 608 card | The certifying organization that gave your exam | Name and approximate test date |
The EPA publishes the list of certified reclaimers and the list of approved Section 608 certifying organizations. How reclaim works at a drop-off point is under how a reclaim drop-off works.
CU5How to ask
Lead with the equipment, then the part, then the numbers: "Three ton heat pump, this model, I need the dual run capacitor, 45 over 5 at 440." That order lets the counter person check your numbers against what the unit should have, which catches the case where the last person fitted the wrong part.
- Say what the part does, if you do not know its name. "The switch on the burner box with the red button" is a rollout switch.
- Ask whether the replacement is the original equipment part or a universal one, and what differs, such as mounting or wire leads.
- Ask what else is normally replaced with it. A new motor wants a new capacitor. An opened refrigerant circuit wants a new filter drier.
- Ask about returns before buying electrical parts. Many counters do not take them back once installed.
New to all of this? The category index shows how a supply house is laid out, and about this reference explains how the pages work.