Northaire Supply

HVAC/R parts and supplies reference

Parts and supplies by category

A supply house is laid out by category, and so is this reference. Find the aisle below, or go straight to the tube chart, which is the lookup people need most often.

PR1Category index

CategoryWhat is in itYou specify it by
FiltersThrowaway, pleated and deep media filters, washable filtersActual size, depth, MERV
ControlsThermostats and wire, capacitors, contactors, relays, transformers, pressure and limit switches, ignitorsVoltage, microfarads, amps, poles, cut-in and cut-out
ChemicalsCoil cleaners, condensate pan and drain treatments, leak detectors, oilsCoil type and location, refrigerant, pH class
Compressors, motors, pumpsCompressors, fan and blower motors, condensate pumps, hydronic circulatorsNameplate data, refrigerant, lift and flow
Duct and sheet metalRound pipe and fittings, flex duct, duct board, tapes, mastic, insulationDiameter, gauge, R-value, UL 181 listing
EquipmentSplit and packaged systems, ductless, ice machines, portable spot coolersCapacity, voltage and phase, refrigerant, matched combination
Certification and reclaimEPA Section 608, refrigerant status, recovery cylinders, reclaimCertification type, refrigerant, cylinder weight

PR2ACR copper tube sizes

ACR tube, the copper made for air conditioning and refrigeration, is named by its actual outside diameter (OD). Plumbing copper (Types K, L and M) is named by a nominal size that is 1/8 in smaller than its OD. The two systems overlap, which is why a 7/8 ACR suction line and a "3/4 inch" plumbing pipe are the same diameter. Ask for tube by OD and say "ACR" and nobody has to guess.

1 inch at this scale1/41/8 nom.5/16no match3/81/4 nom.1/23/8 nom.5/81/2 nom.3/45/8 nom.7/83/4 nom.1-1/81 nom.1-3/81-1/4 nom.
Cross-sections at relative scale. Wall thickness is drawn to the same scale.
ACR tube, soft annealed coils (ASTM B280)
ACR size (OD, in)OD, decimal inSame OD as plumbing nominalWall, in
1/40.2501/80.030
5/160.312No plumbing equivalent0.032
3/80.3751/40.032
1/20.5003/80.032
5/80.6251/20.035
3/40.7505/80.035
7/80.8753/40.045
1-1/81.12510.050
1-3/81.3751-1/40.055

What makes tube "ACR" is not only the naming. It is cleaned and dehydrated at the mill and shipped sealed, with capped ends on straight lengths and plugged ends on coils, so the inside is dry and free of oil and scale. Plumbing tube from the same rack size is not prepared that way and does not belong in a refrigerant circuit. Keep the caps on until the moment you connect it.

Soft or hard drawn

Soft (annealed)Hard drawn
Sold asCoils, commonly 50 ftStraight lengths, commonly 20 ft
BendsBy hand or with a benderDoes not bend. Use fittings
Joins byFlare or brazeBraze. It cannot be flared without annealing
Typical useLine sets, short runs to the unitLong exposed runs, risers, commercial piping

Pre-insulated line sets are soft ACR tube in pairs, a small liquid line and a larger insulated suction (vapor) line. They are ordered by both diameters and the length, for example 3/8 by 3/4 by 50 ft. The equipment installation manual gives the line sizes for the capacity and length of run. Do not size from the old line set alone.

Flare or braze

  • Flare. A 45 degree flare on soft tube, sealed by a flare nut against a matching fitting. Standard on ductless equipment. Use a flaring tool made for current high-pressure refrigerants, deburr without thinning the tube, and tighten with a torque wrench to the equipment maker's value. A flare can be remade. A flare that weeps is the most common ductless leak.
  • Braze. A permanent joint made above 840 °F with filler metal. Copper to copper is done with a phosphorus-bearing copper alloy (BCuP), which needs no flux. Copper to brass or steel needs a silver alloy (BAg) and flux. Flow dry nitrogen through the tube while brazing so black oxide scale does not form inside and end up in the metering device.
  • Press. Mechanical press fittings rated for refrigerant are a third option. They need the matching tool and jaws and must be listed for the refrigerant and pressure.

Soft solder of the plumbing kind is not used on refrigerant lines.

PR3What to bring to any counter

Parts are found by number first, description second. In order of usefulness (the part-by-part version is on before you go to the counter):

  1. The equipment data plate: brand, full model number and serial number. A phone photo is fine if it is sharp.
  2. The old part, with its label. Original equipment part numbers cross-reference to universal replacements.
  3. The electrical facts: line voltage, phase, and control voltage.
  4. For anything touching the refrigerant circuit, the refrigerant type from the data plate and your Section 608 card.
  5. Measurements where numbers are missing: shaft diameter, body diameter, mounting hole spacing, tube OD.

Category pages go deeper: controls for anything electrical, compressors, motors and pumps for nameplates, and equipment for whole units.